DIMENSIONS AND SPECIFICATIONS, XG24-JIB MODEL

Model

Total

kW

Load

Loading kW Per Phase

Nominal Amps Per Line

208/240V 3ph

208V 3-Phase Delta 240V 3-Phase Delta

X-Y

X-Z

Y-Z

X

Y

Z

X

Y

Z

XG24-JIB

8.66

2.66

3.33

2.66

24.90 22.14 24.90 21.61 19.19 21.61

6’ (1.83m) electric cord and plug included in supplied accessory kit: 240V models are supplied with a #4-10AWG

cord with a NEMA 5-30P plug, kit # 4525509. 208V models are supplied with a #4-6AWG cord with a NEMA 15-50P

plug, kit # 4524785.

Clearances

Gas Pressure

Total Gas Input

Entry

Installation

Supply (min.)

Operating

Crated

Uncrated

Sides

Rear

NAT

PRO

NAT

PRO

BTU/Hr

kW

47-1/2"

(1207mm)

32"

(813mm)

6"

(152mm)

3"

(76mm)

7.0" WC 11.0" WC 3.5" WC

3.5 " WC 66,000

19.4

G

9"

[229mm]

TOLERANCE

+/- 1/8" [3mm]

26 3/16"

[665mm]

GRILL

PLATE

HEIGHT

35 5/8"

[905mm]

3/4"

GAS INLET

61 1/4"

[1556mm]

RIGHT SIDE VIEW

34"

[864mm]

MIN 6"

[152mm]

MAX 9"

[229mm]

TOP VIEW

24"

[610mm]

1 3/4"

[44mm]

40"

[1016mm]

35"

[889mm]

TOP HEATER

11 1/2"

[292mm]

GRILL PLATE 24" X 24"

[610mm X 610mm]

FRONT

VIEW

Shipping: Weight 575Lbs/ 234Kg, 45 Cubic Feet
Garland products are not approved or authorized for home or

residential use, but are intended for commercial applications

only. Garland will not provide service, warranty, maintenance

or support of any kind other than in commercial applications
Gas input ratings shown here are for installations up to 2,000

Ft. (610m) above sea level. Specify altitudes over 2,000 Ft.