Controller Displays “MOTOR OVER CURRENT” - Platen does not move at all

NO

YES

YES

NO

YES

YES

YES

NO

NO

YES

Check voltage of limit

switches. 5.6 VDC when

switch is Open, 0 VDC when

switches are closed.

Check for 120 volts at the

motor speed controller. Pins

3 & 4.

Possible broken connection

between the motor speed

controller and the terminal

block, terminal marked “SW”.

Replace defective Limit

Switch

Check for 120 - 140 VDC on

pins 1 & 2 or Motor Speed

Controller.

Check for positive

connection at input leads

of Linear Actuator.

Check for binded actuator by

disconnecting the upper

mounting pin, and manually

spinning actuator shaft.

Replace defective linear

actuator.

Replace defective Motor

Speed Controller.

From behind the unit

manually raise and lower the

platen by lifting up on the

platen arms.

Replace worn or damaged

components.

Controller Displays “MOTOR OVER CURRENT” - Platen stops and moves to lower limit

NO

YES

YES

Check voltage of upper limit

switches while platen is in the

upward movement.

Does Upper Limit

Switch change states of 5.6

VDC to 0 VDC?

Replace faulty Upper Limit

Switch.

Replace defective Motor

Speed Controller.