UNIT INSTALLATION

continued

B. Install the nipple assembly into the elbow (3/4” NPT)

Refer to Photo A

C. Install the manifold support bracket over the nipple

attaching it to the circular bracket on the nipple. Do not

tighten screws. Refer to Photo B

Photo B

D. Adjust the manifold support bracket flush with the rear

gas support bracket. Refer to Photo B

E. Tighten the loose screws of the manifold support bracket.

Refer to Photo B

F. Lock the two brackets together using two screws. Refer to

Photo C

Photo C

Accessory Kit – Electrical Supply Lines:

The accessory kit also contains electric power cord and

plug and has a stain relief suited for each unit. Refer to Plug

Configuration in SPECIFICATIONS and Photo D

Installation of Cord And Plug With Strain Relief:

1. Remove the left grease bucket support attached by two

metal screws and the stainless steel left side body panel

attached by five metal screws.

2. Remove the cord & plug and strain relief assembly from

the accessory kit. Refer to photo D.

Photo D

3. Remove the locknut from at the end of the cord. Refer to

photo E.

Photo E