Technical troubleshooting, Continued – Garland JACK IN THE BOX XG36-JIB User Manual

Page 45

Advertising
background image

Part # JIBSM08 Rev.6 (08/04/09)

Page 45

TECHNICAL TROUBLESHOOTING

continued

NO

Check for 120VAC output from

ignition module, terminal

VALVE & VALVE.

NO

YES

NO

YES

NO

YES

Check micrpamp reading between

Ignition Module and Ignitor. UA

Reading should be between .8 and 1.6

Ideal microamps is between 1.0 and 1.2

YES

NO

YES

YES

Dig Gas Valve Open?

Check for 120 VAC across gas

Valve, terminal 3&4

Check for 3.5” W.C. (NAT

GAS), 10” W.C. (LP)

burner pressure.

Check gas view port

to ensure flame is lighting.

Is Burner lighting at all?

Check for any obstructions

in gas piping and repair

as needed

Adjust gas

pressure

Replace Ignition

Module

Adjust UA reading until

recommended UA are

obtained.

Replace Ignitor

Check wiring connections

between Ignition Module,

and Gas Valve.

Replace gas

valve

Controller Displays “IGNITION FAILURE” - Module is sparking, flame comes on and goes out