Technical troubleshooting, Continued – Garland JACK IN THE BOX XG36-JIB User Manual

Page 38

Advertising
background image

Part # JIBSM08 Rev 7 (08/04/09)

Page 38

Controller Displays “FAULTY ELEMENT OR SHORTED PROBE” -

Only 1 or 2 zones LED lights are RED

NO

YE S

YES

YE S

YE S

YE S

NO

NO

NO

NO

NO

NO

NO

NO

Check for 3-phase

voltage at primary

side of main contactors

Check to ensure that 3-phase

power cords are securely

fastened and plugged

into their receptacles

Fasten & plug in 3 phase

power cords

Check for 3-phase

voltage at secondary

side contactor

Ensure that main 3-phase circuite

breakers are not tripped

or turned off

Check for Soild State Relay

Closure by measuring

approx 0 VAC on output

Replace effected

Solid State Relay

Replace Bad Contactor

Check for disconnected or

damaged molex plugs

going to heating elements

Check for full line voltage

at effected heating element

Replace heating element

Check for a full amperage

draw on effected element

Check for approx. 8.9 VDC

at input side of effected

heat zone’s Solid State Relay

Check for loose pins or damaged

wires from Controller routed

to effected zone’s

Solid State Relay

Replace Main Controller

TECHNICAL TROUBLESHOOTING

continued

Advertising
This manual is related to the following products: