Master Power (ON / OFF) Switch turned ON - Power Light in On - Grill is not heating

YES

YES

NO

YES

YES

NO

NO

NO

YES

NO

Controller display

reads “OFF”

High voltage power

cord(s) unplugged

High voltage circuit breaker at

service panel is OFF or tripped

Check for 120 VAC at terminal

block between LIM & NEUT

Test continuity on contactor

coil between LIM & NEUT

Replace defective contactor

Press the MENU SELECT

button.

Reconnect power supply

Reset circuit breaker

Disconnect power supply

and perform continuity test

on terminals of high limit

in upper platen

Replace defective high limit