Turn Master power switch “ON”, wait for controllers to display

“OFF”.

Note: Release sheets should not be installed during this

procedure.

1. Press and hold for three, (3) seconds. “ENTER CODE” is

displayed.

2. Using the Product buttons, 0-9 enter the code, (1251).

“ENTER CODE **** ” is displayed.

3. Press to enter the Programming Mode.

“PROGRAMMING MODE MENU ITEMS” is displayed.

4. Press two, (2) times in succession to display

“PROGRAMMING MODE SYSTEM SETUP.”

5. Press six, (6) times. “PLATEN SET +/- XX” is displayed.

(XX=numbers that will vary from grill to grill.)

6. Allow time for grill to heat and turn ready. Press

both the Cancel (Green) and Standby (Black) buttons

simultaneously to lower the upper platen. Press the

Cancel (Green) button to raise the platen. Now, press

both the Cancel (Green) and (Black) Buttons to re-lower

the platen.

7. Remove platen adjuster caps from all four adjustment

points on each platen. Remove the four locking caps from

the adjustment points.

8. Using the adjusting tool lower platen until adjusting tool

touches the arm assembly.

9. With gapping tool, adjust right rear of platen until the

gapping tool fits snugly between the upper platen and

grill surface.

10. Move next to the left front adjuster and raise the platen

until the gapping tool fits snugly between the upper

platen and grill surface.

11. Next go to the left rear adjuster and raise the platen until

the gapping tool fits snugly between the upper platen

and grill surface.

12. Move next to the right front adjustment and raise the

platen until the gapping tool fits snugly between the

upper platen and grill surface.

13. Repeat steps 9-12 one or more times until gapping tool

fits snugly between the upper platen and grill surface at

all four adjustment points without further adjustment.

(See diagram below.)

14. Replace the platen adjuster locking caps “hollow side

down” and tighten snugly. Replace platen adjuster caps.

15. Repeat steps 9-14 for each platen.

Insert gap tool directly below platen adjusters.