Sanyo KHH2672R / CH2672R User Manual

Page 39

Advertising
background image

1

2

3

4

5

6

I-35

SM831148

1. Specifications

1-2 Major Component Specifications

(A) Indoor Unit

MODEL No.

UH2672R

Source

230 - 208 V / 1 phase / 60 Hz

Remote controller (Option)

Wired or Wireless (See Unit Specification)

Controller P. C. B Ass'y

CR - TH2672

Control circuit fuse

250 V, 5 A

Fan (Number … diameter)

in.

(mm)

Centrifugal (4 ... 5-29/32(150))

Fan motor

Model

KFG4X - 71B6P

Source

230 - 208 V / 1 phase / 60 Hz

No. of pole … r.p.m. (230 V, High)

rpm

4 ... 920

Nominal output

W

100

Coil resistance

BRW - WHT

:

74.7

,

ORG - YEL

:

9.59

(Ambient temperature 68

°F)

WHT - VLT

:

19.1

,

YEL

- BLK

:

10.52

VLT

- ORG

:

10.5

,

BLK

- PNK

:

21.72

Safety device

Operating temperature

Open

°F

266

± 14.4

Close

°F

174.2

± 27

Run capacitor

VAC,

µF

440 V , 5

µF

Heat exchanger

Coil

Aluminum plate fin / Copper tube

Rows … Fins per inch

3 … 14.9

Face area

ft.

2

(m

2

)

2.03 (0.189)

DATA SUBJECT TO CHANGE WITHOUT NOTICE

Advertising