1. Specifications

1-2 Major Component Specifications

(A) Indoor Unit

MODEL No.

KH3672R

Source

230 - 208 V / 1 phase / 60 Hz

Remote controller (Option)

Wired or Wireless (See Unit Specification)

Controller P. C. B Ass'y

CR - TH2672

Control circuit fuse

250 V, 5 A

Fan

Cross-flow

Number ... Dia. and length

in.

(mm)

1 ... O.D. 4-13/18 (120), L46 (1,170)

Fan motor

Model

SFG4Q - 41B6P

Source

230 - 208 V / 1 phase / 60 Hz

No. of pole ... r.p.m. (230 V, High)

rpm

4 ... 1,273

Nominal output

W

50

Coil resistance

GRY - WHT

: 122.3

,

ORG - YEL

:

23.03

(Ambient temperature 68

°F)

WHT - VLT

:

15.98

,

YEL

- PNK

:

9.272

VLT

- ORG

:

11.93

,

Safety device

Operating temperature

Open

°F

266

± 14.4

Close

°F

174.2

± 26

Run capacitor

VAC,

µF

440 V , 4

µF

Heat exchanger

Coil

Aluminum plate fin / Copper tube

Rows ... Fins per inch

3 ... 12.7

Face area

ft.

2

(m

2

)

3.23 (0.3)

Louver Motor

Model

M2EA24ZA01

Rating

208 to 230 V, 60 Hz

No. of pole ... rpm

8 ... 3

Output

W

2.5

Coil resistance (Ambient temperature 68

°F)

k

16.45

± 8 %

DATA SUBJECT TO CHANGE WITHOUT NOTICE