Sanyo KHH2672R / CH2672R User Manual

Page 44

Advertising
background image

1

2

3

4

5

6

I-40

SM831148

1. Specifications

1-2 Major Component Specifications

(A) Indoor Unit

MODEL No.

KHH2672R

Source

230 - 208 V / 1 phase / 60 Hz

Remote controller (Option)

Wired or Wireless (See Unit Specification)

Controller P. C. B Ass'y

CR - TH2672

Control circuit fuse

250 V, 5 A

Fan

Cross-flow

Number ... Dia. and length

in.

(mm)

1 ... O.D. 4-1/3 (110), L39 (990)

Fan motor

Model

UF4Q - 31A6P

Source

230 - 208 V / 1 phase / 60 Hz

No. of pole ... r.p.m. (230 V, High)

rpm

4 ... 1,277

Nominal output

W

30

Coil resistance

BRW - WHT

: 197.2

,

ORG - YEL

:

59.1

(Ambient temperature 68

°F)

WHT - VLT

:

41.4

,

YEL

- PNK

:

48.8

VLT

- ORG

:

22.2

,

Safety device

Operating temperature

Open

°F

248

±

9

Close

°F

171

± 27

Run capacitor

VAC,

µF

440 V , 1.8

µF

Heat exchanger

Coil

Aluminum plate fin / Copper tube

Rows ...

3 ... 12.7

Face area

ft.

2

(m

2

)

2.57 (0.24)

Louver Motor

Model

M2EA24ZA01

Rating

208 to 230 V, 60 Hz

No. of pole ... rpm

8 ... 3

Output

W

2.5

Coil resistance (Ambient temperature 68

°F)

k

16.45

± 8 %

DATA SUBJECT TO CHANGE WITHOUT NOTICE

Heater Element (Aux. Heater)

Model

AH - KH2412

1.8 / 1.5

Input (230 / 208 V)

KW

Protective thermostat

OFF 140

± 5°F, ON 113 ± 9°F

Thermo fuse

Cut - off 370 + 2, - 5

°F, 277V - 15A