C.1.3 diags get state, C.1.3.1 command, C.1.3.2 return codes – Sun Microsystems Sun Fire V20z User Manual

Page 101

Advertising
background image

Appendix C

Diagnostics Commands

C-3

C.1.3

diags get state

C.1.3.1

Command

Access: Administrators

Description: Returns the state of the platform diagnostics control server.

Command format: diags get state

If you get a success text message returned from the command, the platform is up
and ready for diagnostics and you can submit platform diagnostic tests for
execution.

If you get an error text message, the platform diagnostics are not up, and you will
need to wait to run the platform diagnostics tests.

C.1.3.2

Return Codes

Following are the return values for this command:

NWSE_RPCNotConnected

3

Unable to connect to the RPC server.

NWSE_InvalidArgument

4

One or more arguments were incorrect or
invalid.

NWSE_NoPermission

6

Not authorized to perform operation.

NWSE_MissingArgument

7

Missing argument(s).

Return Code

ID

Description

NWSE_Success

0

Command successfully completed.

NWSE_InvalidUsage

1

Invalid usage: bad parameter usage,
conflicting options specified.

NWSE_DeviceError

25

Unable to read or write to the device.

Return Code

ID

Description

Advertising