Chapter 4

Maintaining the Server

4-11

5. Remove the center air baffle.

FIGURE 4-11

Removing the Center Air Baffle

6. Remove the second processor fan from the right:

a. Unplug the fan’s power connector from the motherboard.
b. Pull the fan straight up to remove it from the fan tray.

FIGURE 4-12

Removing a Cooling Fan

7. Remove the CPU VRM for CPU 1 (lefthand CPU) by pulling it straight up, out of

its sockets.

FIGURE 4-13

Removing the CPU 1 VRM