Troubleshooting, Problem possible causes possible remedies – North Star M165951C User Manual

Page 31

Advertising
background image

Troubleshooting

31


TROUBLESHOOTING

Problem

Possible Causes

Possible Remedies

Voltage too low

a) Tractor throttle set too low
b) Generator is overloaded

a) Increase tractor RPMs.

b) Reduce the load (See Power Load Planning &

Mgt. section of this manual).

Circuit breaker trips

a) Defective load connected to

generator

b) Defective receptacle

c) Generator is overloaded

d) Defective circuit breaker

a) Disconnect load.

b) Replace receptacle

– Contact Product Support

for the nearest service center.

c) Reduce the load (See Power Load Planning &

Mgt. section of this manual).

d) Contact Product Support for nearest service

center.

Voltage too high

a) Tractor throttle set too high

a) Decrease tractor RPMs.

Generator overheating

a) Generator is overloaded

a) Reduce the load (See Power Load Planning &

Mgt. section of this manual).

No output voltage

a) Defective load connected to

generator

b) Broken or loose wire

c) Defective receptacle

d) Defective stator

e) Defective rotor

f) Defective capacitor

g) Defective circuit breaker

h) Tractor throttle set too low
i) PTO not engaged
j) Gearbox malfunctioning

k) Circuit breaker tripped.

a) Disconnect load.

b) Replace or tighten wire

– Contact Product for

the nearest service center.

c) Replace receptacle

– Contact Product Support

for the nearest service center.

d) Contact Product Support for the nearest

service center.

e) Contact Product Support for the nearest

service center.

f) Contact Product Support for the nearest

service center.

g) Contact Product Support for the nearest

service center.

h) Increase tractor RPMs.
i) Engage PTO.
j) Contact Product Support for the nearest

service center.

k) Reset circuit breaker and reduce loads

connected to the generator.

Excessive gearbox
noise

a) Defective bearing

b) Defective gear

c) No or low gear oil
d) PTO driveline is operating at an

angle of greater than 15


e) Unsynchronized PTO driveline

a) Contact Product Support for the nearest

service center.

b) Contact Product Support for the nearest

service center.

c) Fill gearbox to middle of oil level sight glass.
d) Reposition the tractor or generator so the

angle is reduced to less than 15

both

vertically and horizontally.

e) Disassemble PTO driveline and reassemble

with CV joints synchronized.

Advertising