Appendix D CM-2 Management Commands

Defining Dial-Up Modem Parameters

D-3

Command Fields

Table D-1 lists the fields appearing on the data form.

Table D-1. DEF CALL Fields

Field Name

Description

Options

DIAL MODEM STATUS

Sets the dial modem to active or inactive.

After you set the CM-2 to active status, it becomes

available for use after 10 seconds. A message is shown on
the terminal.

In order to change the modem from active to inactive,

disconnect the terminal port for about one minute.

ACTIVE – Dial-up modem is
active

INACTIVE – Dial-up modem is
inactive

COMMAND

Command to dial-up modem. For example, ATD.

NUM OF RETRIES

Specifies the number of dialing retries:

NUM OF RETRIES applies to both the primary and the

alternate numbers as follows:

• If the call is not established after dialing the primary

number the specified number of times, the CM-2
attempts to establish the call by dialing the alternate

number (provided the use of an alternate number is
enabled by means of the ALT NUM MODE parameter
below).

• If the call cannot be established with the specified

number of redialing attempts on either of the two

numbers, the CM-2 stops the call attempt. When a
new alarm report must be sent, the call attempts are
started again.

The user is notified about a failed call attempt by a
message recorded in the alarm buffer. Separate messages
are provided for each number called.

0 – No redial is attempted if
the call is not established on

the first attempt

1 through 8 – If the call is not
established on the first

attempt, the CM-2 redials the
specified number of times.

WAIT FOR CONNECT

Specifies time that the CM-2 waits for an answer after each

dialing attempt. If the called station does not answer
within the specified time, the CM-2 disconnects. If
additional call attempts are allowed, the CM-2 redials 30

seconds after disconnecting.

30, 45, and 60 seconds

Default value: 60 seconds

DIAL MODE

Selects dialing mode

The appropriate dialing mode to use depends on dialing
mode supported by the network.

TONE – The modem is

instructed to use DTMF dialing

PULSE – The modem is
instructed to use pulse dialing

PHONE NUMBER

Primary phone number

Order from: Cutter Networks