Chapter 2 Installation and Setup

LRS-24 Installation and Operation Manual

2-10

Installation and Setup

Internal Jumpers

Figure 2-5 shows the location of the user-selectable jumpers located on the CM-1
module. Figure 2-3 lists the jumper settings.
The CM-1 module includes additional factory-set jumpers, which must not be
moved by the user.

JP11 LCODE

T1 Line

Code

AMI

E1 Line

Code

HDB3

Interface Selection

Jumpers JP4, JP5, JP6

Balanced
E1 Interface

JP4

JP5

JP6

E1-BAL

JP4

JP5

JP6

T1-DSU

JP4

JP5

JP6

E1-UBAL

Balanced
T1 Interface

Unbalanced
E1 Interface

JP12 RLOOP

Remote Loopback

Toward Station

Clock Source

No Loopback

ON

OFF

Jumper JP9, JP10

Balanced
Clock
Interface

BAL

UNBAL

Unbalanced
Clock
Interface

JP14 STATCLK

Clock at
System
Levels

SYS

TTL

Clock at
TTL Levels

JP15 RCEN

TTL Level
Converter
Enabled

EN

DIS

TTL Level
Converter
Disabled

BAL

JP1

4

JP12

JP1

1

JP

15

RLOOP LCODE

ON

AMI
HDB3

OFF

JP

9

JP4

JP5

JP6

E1-BAL

E1-UBAL

T1-DSU

JP

1

0

UBAL

EN
DIS

RCEN STATCLK

SYS

TTL

Figure 2-5. Module CM-1, Internal Jumpers