4 technical specifications, I/o (user) modules – RAD Data comm LRS-24 User Manual

Page 26

Advertising
background image

Chapter 1 Introduction

LRS-24 Installation and Operation Manual

1-14

Technical Specifications

MBE

MBE

LRS-24

LRS-24

Management

Station

Supervision

Terminal

LRS-24

LRS-24

WAN

Figure 1-8. Basic Management Configuration for LRS-24 with CM-2 Modules

I/O (User) Modules

LRS-24 can be equipped with various types of input/output (I/O) modules to
provide the required system functions. These include ASMi-24C, ASMi-31C,
ASMi-31CQ, ASMi-50C, ASMi-450C, HTU-E1C, FOMi-40C, FOMi-E1/T1C,
FOMi-E3C, FOMi-T3C, MTMi-20C, FOMi-40CD, ASM-40CD, FOMi-E1/T1/CD,
ASMi-50CD, and ASMi-51CQ.
The range of modules and options available for LRS-24 is continuously expanding.
Refer to the Installation and Operation Manuals of the corresponding modules for
information.

1.4 Technical Specifications

Chassis
Characteristics

Number of
Functional Module
Slots

15 – Each slot is connected to an interface module slot

Slot Usage

2 power supply slots
1 common logic slot
12 identical slots for I/O (user) modules

Power

Module
PS-LRS/230/115

100 – 240 VAC nominal, 50/60 Hz, maximum 160W

Module PS-LRS/48

–48 VDC nominal, maximum 160W

Remote (Phantom)
Source

LRS-PS-FEED standalone unit

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com