RAD Data comm LRS-24 User Manual

Page 109

Advertising
background image

LRS-24 Installation and Operation Manual

Appendix D CM-2 Management Commands

Defining LRS-24 And CM-2 SNMP Agent Parameters

D-7

Table D-3 DEF HUB Command Fields (Cont.)

Field Name

Description

Options

BURN IN MAC ADDRESS

Fctory MAC address used by BOOTP server to

declare the IP address of the CM-2.

BOOTP ON/OFF

Toggle to select BOOTP.

To maintain backwards compatibility (with any

LRS-12 version), set BOOTP ON/OFF to OFF.
Otherwise, BOOTP ON/OFF should be set ON.

In either case, BOOTP ON/OFF should be set to

OFF while setting the IP address.

ON– use BOOTP

OFF–no BOOTP.

Default value: OFF

BOOTP TIME OUT

Maximum waiting time for a BOOTP response

1, 2, 3, 4, 6, 8, 10, 15, 20

seconds.

Default value: 10 seconds

BOOTP RETRIES

Number of times to retry sending a request for the

BOOTP server

3, 4, 5, 10, 15, 20, 25, 30 times.

Default value: 30 times

HUB IP MODE

SINGLE – only one IP address.
(The LRS-24 address is the CM-2

address.). CM-2 receives SMOD
message and transfers to it to the
SMOD modem after adjusting

the IP. The IP is resolved from
the community field. In this
mode, ping and Telnet cannot

be used directly on an SMOD;
only the CM-2 IP address is
relevant.

MULTIPLE – normal mode.
Every SMOD has its own IP
address and the CM-2 does not

interfere at the IP level. Every
SMOD IP is calculated by
adding the CM-2 IP address and

the SMOD slot number.

SERIAL LINE PROTOCOL

SLIP Protocol

RS232 – terminal

STATION CLOCK

Set clock for station

Internal

External – Square

Ext-AMI

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Advertising