LRS-24 Installation and Operation Manual

Chapter 2 Installation and Setup

Installation and Setup

2-13

Table 2-4. Module CM-2, Front Panel

Indicator

Function

POWER

Lights up when CM-2 is receiving input power (+5V)

TD

Lights up to indicate activity on the transmit (input) line of

the ETHERNET MANAGEMENT port

RD

Lights up to indicate activity on the receive (output) line of

the ETHERNET MANAGEMENT port

STAT/ADD Display

If a failure is detected during the power-up self-test, displays

a code that identifies the failure type
During normal operation, displays the two least significant

digits of the hub number

MANAGEMENT

RS-232 Connector

Direct connection of supervision terminal to LRS-24

management port

Internal Jumpers

Figure 2-7 shows the location of the user-selectable jumpers located on the CM-2

module.
The module includes additional factory-set jumpers, which must not be moved by
the user.