RAD Data comm LRS-24 User Manual

Page 86

Advertising
background image

Appendix A Connector Wiring

LRS-24 Installation and Operation Manual

A-2

Management RS-232 Port Interface—CM-1/CM-2 Modules

A.2 Management RS-232 Port Interface—LRSI-F-CM1

Module

The Management RS-232 port on the LRSI-F-CM1 module has an RS-232 interface
terminating in a 9-pin female connector wired in accordance with
Table A-2.

Table A-2. Pin Allocation for MANAGEMENT RS-232 Connector

Pin

Function

Direction

1

Data Carrier Detect (DCD)

Output

2

Receive Data (RXD)

Output

3

Transmit Data (TXD)

Input

4

Data Terminal Ready (DTR)

Input

5

Signal Ground (SIG)

N/A

6

Data Set Ready (DSR)

Output

7

Request to Send (RTS)

Input

8

Clear to Send (CTS)

Output

9

Ring Indicator (RI)

Output

A.3 Management RS-232 Port Interface—CM-1/CM-2

Modules

The Management RS-232 port on the CM-1 and CM-2 modules has an RS-232
interface terminating in a 9-pin female connector wired in accordance with
Table A-3.

Table A-3. Pin Allocation for Management RS-232 Connector

on CM-1/CM-2 Modules

Pin

Function

Direction

1

Data Carrier Detect (DCD)

Connected to pins 7, 8

2

Receive Data (RXD)

Output

3

Transmit Data (TXD)

Input

4

Data Terminal Ready (DTR)

Input, connected directly to pin 6

5

Signal Ground (SIG)

N/A

6

Data Set Ready (DSR)

Output, connected directly to pin 4

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Advertising