Pinouts

B-9

B

A

LARM

P

INOUT

Pin Assignments for the Alarm connector are as follows:

Table B-11 Alarm Pinout

Maj

-

Major

Min

-

Minor

NC

-

Normally Closed (unless alarm condition is true

this pin is connected to the appropriate comm pin)

NO

-

Normally Open (only during an alarm condition
will this be connected to the appropriate comm

-

pin)

Alarm in

-

input for an alarm to the device

The above table shows the signal names and pin connections. These
outputs of Major alarms normally open and normally closed, Minor alarms
normally open normally closed, and Alarm in + & - are done through
relays and an optoisolators respectively. They are designed for -48v,
although a lower voltage should work equally well.

PIN

SIGNAL

5

Maj Comm

9

Maj NC

4

Maj NO

8

not connected

3

Alarm in -

7

Min Comm

2

Min NO

6

Min NC

1

Alarm in +