Quick Eagle Networks DL3800E User Manual

Page 48

Advertising
background image

4-8

DL3800E Inverse Multiplexer User’s Guide — July 9, 2001

4

ROM Checksum Fail

This occurs if the checksum for the code
image stored in ROM does not match that
expected.

No Ext Clk

No clock detected on the External Clock
DB-- 9 connector on the back panel.

Primary Clock

The set primary receive clock source is
now providing the network receive clock.

Secondary Clk

The set secondary receive clock source is
now providing the network receive clock.
(Occurs if the primary source has been
lost).

Internal Clk

Loss of Internal Clock.

Sync

Net 1 -- Net Port 1 is the network receive
clock source.

Sync

Net 2 -- Net Port 2 is the network receive
clock source.

Sync

Net 3 -- Net Port 3 is the network receive
clock source.

Sync

Net 4 -- Net Port 4 is the network receive
clock source.

Sync

Net 5 -- Net Port 5 is the network receive
clock source.

Sync

Net 6 --- Net Port 6 is the network receive
clock source.

Sync

Net 7 -- Net Port 7 is the network receive
clock source.

Sync

Net 8 -- Net Port 8 is the network receive
clock source.

No Net Sync

Shows all port are down. More
specifically, if a network clock cannot be
sourced from any port.

DTE

HSSI Channel Lpbk

A HSSI hardware loopback has been set.

User Lpbk

The DTE/Network loopback has been set.

V.35 LT Lpbk

A V.35 hardware loopback has been set.

Table 4-2 3800E Alarm Descriptions

ALARM

DESCRIPTION

Advertising