To delete the entire unit configuration, select DELETE ENTIRE UNIT
CONFIGURATION from the SOFTWARE UTILITIES MENU, and press
Enter

. Use the arrow keys to highlight the Desired Action field. Press the

space bar until RESET ENTIRE NODE DATABASE TO FACTORY
DEFAULTS appears in the field. The change must then be confirmed. Move
the highlight bar to CONFIRM, and press the Enter key. Deleting the
entire node configuration puts all parameters back to their Factory Default
Settings.

From the SOFTWARE UTILITIES MENU (

Figure 4-17 on page 4-36

) you

may also perform the following functions:

• Delete RAM code and Revert to ROM code

• Restart Node Software

Figure 4-17

SOFTWARE UTILITIES MENU

Delete RAM Code and Revert to ROM Code

To delete RAM code and revert to ROM code, select DELETE ENTIRE
UNIT CONFIGURATION from the SOFTWARE UTILITIES MENU, and
press Enter. Use the arrow keys to highlight the Desired Action field.
Press the space bar until DELETE RAM CODE AND REVERT TO ROM
CODE appears in the field. The change must then be confirmed. Move the
highlight bar to CONFIRM, and press Enter.

Restart Node Software

Restart Node Software resets the unit without powering down.

Major 01/01/90 04:58:17 Unit: 0 NET : 2 (114)

Network 15 Minute UAS Major Threshold Exceeded

Major 01/01/90 04:58:17 Unit: 0 NET : 1 (114)

Network 15 Minute UAS Major Threshold Exceeded

DIGITAL LINK DL3800E SR 2.00.00 NODE 7: 01/01/90 05:55:07 MJ

SELECTED DEVICE ADDRESS: 7.00.000 NAME:

DELETE ENTIRE UNIT CONFIGURATION Exit

DESIRED ACTION: None

DO YOU REALLY WANT TO DO THIS? PLEASE CONFIRM:

Confirm