DL3800E Inverse Multiplexer User’s Guide — July 9, 2001

1

Setup

Terminal Log On

Connect your terminal to the COMM port on the back of the DL3800E unit.
Before you can log into the unit, you must make sure that terminal settings
match the DL3800E. Defaults for the DL3800E unit COMM port: 9600
baud, no parity, 8 bit word length, 2 stop bits. To log into the unit, first
press Ctrl-x five times (that is, hold down the control key on the
keyboard and press the x key five times. This gives you the unit number.
Now type Ctrl-x # Unit Number and press Return or Enter. When
prompted for user name and password press Return twice, and the Main
Menu on the DL3800E unit should appear. The default unit number is 0.

Terminal Configuration

Change only the configuration items listed below. Leave the other options
at the factory default settings. To make a change, note that you must press
the UP and DOWN ARROW keys to highlight the item, press the space bar
until the desired option displays, then highlight CONFIRM and press Enter
before exiting the menu.

Unit Configuration

Select Configuration from the Main Menu. Select Unit Configuration. Set
the time and date. Set unit number other than zero. Select Confirm, then
select EXIT to go back to the CONFIGURATION MENU.

DTE Configuration

Configure the DTE interface for either v.35/RS449/x.21 or HSSI. For
V.35/RS449/X.21 configuration, set the clock to SCTE and Normal TD/RD
clock.

Set the DTE loss condition for NONE. Select Confirm, then select

EXIT

to go back to the CONFIGURATION MENU.

WARNING: V.35/RS449/X.21 will only work at a higher data rate
with a DTE that can give terminal clocking, when in SCTE mode.