Quick Eagle Networks DL3800E User Manual
Page 56
4-16
DL3800E Inverse Multiplexer User’s Guide — July 9, 2001
4
To clear the report of all History Events, move the highlight bar to CLEAR
HISTORY and press Enter.
Figure 4-6
is an example.
Figure 4-6
EVENT HISTORY MENU
Table 4-4 Alarm Level
Alarm Parameter
Definition
Alarm Level:
Major
Minor
Idled
Status
Service affecting
Needs attention, not yet service affecting
Alarm condition has expired
Non-service-affecting event
Date and Time
Date and time of the occurrence or expiration of the alarm/state
Address
The address is the physical location
Device
The device reporting the status and alarm condition (Unit #), and the type of device
(NET, DTE, or NODE)
Event Code
Number designation for type of alarm or status condition. This number will be
useful when contacting the factory
Description
Describes the event
Major
01/01/90 17:56:47 Unit: 1NET : 2(33)
Loss of Frame
Idled
01/01/90 17:56:58 Unit: 1NET : 2(13)
Loss of Frame Idled
DIGITAL LINK DL3800E SR 2.00.000 NODE 7:HOME 01/01/90
03:14:54 MN SELECTED DEVICE ADDRESS: 7.00.000NAME:HOME
EVENT HISTORY Exit Repeat Clear History Page 1
Idled
01/01/9009:02:10Unit 1 NET 2
(29)
Yellow Signal Detected Idled
Major
01/01/9009:02:06Unit 1 NET 2
(30)
Yellow Alarm
Status
01/01/9008:58:09Unit 1 NET 2
(29)
Yellow Signal Detected
Idled
01/01/9008:58:01Unit 2 NET 3
(29)
Yellow Signal Detected Idled
Minor
01/01/9008:56:24Unit 1 Node
(36)
ROM Checksum Failed