4-16

DL3800E Inverse Multiplexer User’s Guide — July 9, 2001

4

To clear the report of all History Events, move the highlight bar to CLEAR
HISTORY and press Enter.

Figure 4-6

is an example.

Figure 4-6

EVENT HISTORY MENU

Table 4-4 Alarm Level

Alarm Parameter

Definition

Alarm Level:
Major
Minor
Idled
Status

Service affecting
Needs attention, not yet service affecting
Alarm condition has expired
Non-service-affecting event

Date and Time

Date and time of the occurrence or expiration of the alarm/state

Address

The address is the physical location

Device

The device reporting the status and alarm condition (Unit #), and the type of device
(NET, DTE, or NODE)

Event Code

Number designation for type of alarm or status condition. This number will be
useful when contacting the factory

Description

Describes the event

Major

01/01/90 17:56:47 Unit: 1NET : 2(33)

Loss of Frame

Idled

01/01/90 17:56:58 Unit: 1NET : 2(13)

Loss of Frame Idled

DIGITAL LINK DL3800E SR 2.00.000 NODE 7:HOME 01/01/90

03:14:54 MN SELECTED DEVICE ADDRESS: 7.00.000NAME:HOME

EVENT HISTORY Exit Repeat Clear History Page 1

Idled

01/01/9009:02:10Unit 1 NET 2

(29)

Yellow Signal Detected Idled

Major

01/01/9009:02:06Unit 1 NET 2

(30)

Yellow Alarm

Status

01/01/9008:58:09Unit 1 NET 2

(29)

Yellow Signal Detected

Idled

01/01/9008:58:01Unit 2 NET 3

(29)

Yellow Signal Detected Idled

Minor

01/01/9008:56:24Unit 1 Node

(36)

ROM Checksum Failed