Dl3800 inverse mux select remote display test, Configuration – Quick Eagle Networks DL3800E User Manual

Page 94

Advertising
background image

5-6

DL3800E Inverse Multiplexer User’s Guide — July 9, 2001

5

This menu loop may also be entered at any time by pressing the Exit
button to go up the menu hierarchy until reaching the TOP MENU.
Continuing to press Exit while in the TOP MENU brings the unit to the
default display

DL3800E INVERSE MULTIPLEXER

scrolling across the

screen. Pressing the UP and DOWN ARROW buttons get you into the
menu loop. A menu is selected by pressing Enter when the menu name
appears on the display.

The DISPLAY MENU is used for displaying Node Status, DTE Status, and
Status of each installed E1 network. The 24-hour line data is only available
with the terminal interface or through the Network Manager. The data in
the DISPLAY MENU is a subset of the parameters that are available on the
ALARM AND STATUS MENU through the terminal interface, or the
Network Manager.

The TEST MENU is used for DTE and Network loopbacks. The DL3800E
unit does not allow performing tests on the remote unit through the front
panel user interface. This feature is only available with the terminal
interface.

Test Menu

DL3800 Inverse Mux

SELECT REMOTE

DISPLAY

TEST

Select Remote/Local

Display Menu

ENTER

EXIT

ENTER

EXIT

ENTER

EXIT

EXIT

EXIT

EXIT

CONFIGURATION

ENTER

EXIT

Configuration Menu

EXIT