Quick Eagle Networks DL3800E User Manual

Page 47

Advertising
background image

Terminal Interface

4-7

4

SES Threshold

Net Port has exceeded the Severely
Errored Second Threshold.

UAS Threshold

Net Port has exceeded the Unavailable
Second Threshold.

BPV MN/MJ

Net Port has declared a Bipolar Violation
Major or Minor Alarm.

OOF MN/MJ

Net Port has declared an Out Of Frame
Major or Minor Alarm.

BPVs 15 Min. MN/MJ

Net Port has declared a Bipolar Violation
15 minute Major or Minor Alarm

CRCs 15 Min. MN/MJ

Net Port has declared a CRC 15 minute
Major or Minor Alarm

ES 15 Min. MN/MJ

Net Port has declared a Errored Second
15 minute Major or Minor Alarm

SES 15 Min. MN/MJ

Net Port has declared a Severely Errored
Second 15 minute Major or Minor Alarm.

UAS 15 Min. MN/MJ

Net Port has declared a Unavailable
Second 15 minute Major or Minor Alarm.

BPVs 24 Hr MN/MJ

Net Port has declared a Bipolar Violation
24 Hour Major or Minor Alarm.

CRCs 24 Hr MN/MJ

Net Port has declared a CRC 24 Hour
Major or Minor Alarm.

ES 24 Hr MN/MJ

Net Port has declared a Errored Second
24 Hour Major or Minor Alarm.

SES 24 Hr MN/MJ

Net Port has declared a Severely Errored
Second 24 Hour Major or Minor Alarm.

UAS 24 Hr MN/MJ

Net Port has declared a Unavailable
Second 24 Hour Major or Minor Alarm.

COMMON EQUIPMENT

External Alarm

An External Alarm has been detected. This
alarm is based on the External Alarm
contacts on the back panel.

Proc Restart

Unit has rebooted.

RAM Test Fail

This occurs if the unit’s RAM does not pass
the memory test which occurs at startup.

Table 4-2 3800E Alarm Descriptions

ALARM

DESCRIPTION