- 41 -
(2) Total count display
F 9 9 9 9 9 9 9 9 C
“C” is displayed when counting is in progress.
Total value is displayed in the unit of count 
When the count exceeds the maximum value of 
99999999, the count will be reset to 0 and will be 
counted again. 
In the case of forward flow count, “F” is displayed. 
In the case of reverse flow count, “R” is displayed. 
 
(3) Total flow value display 
Displayed to the least significant digit of the set pulse 
rate. 
F 9 9 9 . 9 9 m l
C
“C” is displayed when counting is in progress.
Flow
unit
Numeric value is indicated in 8 digits including a 
decimal point. 
(Total valve is displayed up to 99999999, and when 
the total count exceeds the maximum value of 
99999999, the total valve will be reset to 0 and will be 
counted again.) 
In the case of forward flow count, “F” is displayed. 
In the case of reverse flow count, “R” is displayed. 
 
(4) Total difference flow value display 
Displayed to the least significant digit of the set pulse 
rate. 
+ 9 9 9 . 9 9 m l
C
“C” is displayed when counting is in progress.
Flow
unit
Numeric value is indicated up to 8 digits including a 
decimal point. 
If forward flow count ≧ reverse flow count, “+” is 
displayed. 
If reverse flow count › forward flow count, “
−” is
displayed.
For total difference flow value, the difference between the forward direction value and the reverse 
direction value is displayed.