6 normal indicating unit – Toshiba Tohsiba Electromagnetic Flowmeter Converter L5232 User Manual

Page 67

Advertising
background image

6F8A0917

- 66 -

8.2.6 Normal

Indicating

Unit

You can select one of the units listed below as normal indicating unit for 2 types of units, main unit
(UNIT 1) and sub unit (UNIT 2) to be displayed in the measurement mode.

• Flow velocity unit: m/s, ft/s
• Flow rate unit:

m

3

/s, m

3

/min, m

3

/h, m

3

/d

l/s, l/min, l/h, l/d
ml/s, ml/min, ml/h, ml/d
gal/s, gal/min, gal/h, gal/d
bbl/s, bbl/min, bbl/h, bbl/d
pt/s, pt/min, pt/h, pt/d
qt/s, qt/min, qt/h, qt/d

• Volumetric flow: m

3

, l, ml, gal, bbl, pt, qt

• Other units:

%, COUNT, RANGE, CUSTOM

%:

Indicates the value in percent of the setting range
When multi-range is selected, the value is in percent of the range in operation.

COUNT: Indicates the count of the totalizer.

RANGE: Indicates the range number of the range in operation when multi-range is selected.

CUSTOM: Indicates the flow rate value in the unit defined in 8.2.7 “Custom Unit.”

If the unit is set to volumetric flow or COUNT, the flow direction for total flow can be
set.

If the indicting unit is set to volumetric flow or COUNT, the flow direction for total flow can also
be set.

• Volumetric flow direction: F: Forward direction, R: Reverse direction

B: Forward/Reverse automatic switching, D: Total difference flow

indication

Checking the normal indicating unit

Proceed as follows to check the normal indicating unit.
Here, only about the main unit (UNIT1) is explained. For sub unit (UNIT2), select the function
number “B2”.

Switch operation

Display example

Description

B1: UNIT 1
%

Select B1: UNIT 1 from the setting item selection menu.
The currently set main indicating unit appears.

B1: UNIT 1

Returns to the menu of setting item selection.

Advertising