PROGRAMMING PROCEDURES-INSTRUCTIONS/SYSTEM RECORDS
SECTION 100-816-302
MARCH 1993

2-88

PROGRAM 77-1

PERIPHERAL OPTIONS

(DOOR PHONES/IMDU/BASE UNIT RELAY/PIOU/PIOUS)

7

7

P

S

H

H

Z

Z

Light the button/LEDs that are marked
with an X in the table below.

Button/LED

LED

20

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

SELECT = 1

S

1

X

LED ON

LED OFF

Door Lock Time/6 sec.

DDCB2 on DK8/Port 03; DK16/Port 12

DDCB1 on DK8/Port 02; DK16/Port 04

IMDU Modem (Station 619) Enabled

Door Lock Time/3 sec.

DKT on DK8/Port 03; DK16/Port 12

DKT on DK8/Port 02; DK16/Port 04

Door Phone Ring on Ext Page

Door Lock Relay Enabled (PIOU/PIOUS)

NT Relay During Night Ringing and NT1

MOH Relay Enabled (PIOU/PIOUS)

LED 01 Has Priority

7

MOH on Base Unit Relay Enabled

7

IMDU Modem (Station 619)/Disabled

No Ring over Ext Page

External Page Relay Enabled (PIOU/PIOUS)

NT Relay Steady With NT1 Button

NT Relay Enabled (PIOU/PIOUS)

External Page on Base Unit Relay Enabled

7

NT on Base Unit Relay Enabled

7

4

5

6

4

5

6

Tenant 2 (NT2) CO lines – K4/Zone 4

Tenant 2 (NT2) CO lines – K3/Zone 3

Tenant 2 (NT2) CO lines – K2/Zone 2

Tenant 2 (NT2) CO lines – K1/Zone 1

Tenant 1 (NT1) CO lines – K4/Zone 4

Tenant 1 (NT1) CO lines – K3/Zone 3

Tenant 1 (NT1) CO lines – K2/Zone 2

Tenant 1 (NT1) CO lines – K1/Zone 1

8

8

8

8

NOTE: Shaded areas apply to DK16 only

9

NOTES:

1. For more information, see the instructions preceding the record sheets.
2. Initialized data leaves all LEDs off.
3. Port 12 is in the DK16 Expansion Unit.
4. If a modem unit (IMDU) is installed on a DK16 PIOU or PIOUS, it can be accessed by dialing station 619.
5. If NT1 is turned on at an electronic or digital telephone, then the door phone will ring over external page.
6. This option applies to the PIOU/PIOUS Door Lock Control (Unlock Door0) assigned to digital or electronic

telephones using Code 71 in Program 39; it does not apply to DDCB door locks (Unlock Door1 ~ 2).

7. To program the DK8 or DK16 Key Service Unit relay for the MOH function, LEDs 02 and 01 must be ON;

for the NT function, LED 02 must be ON and LED 01 OFF; for the External Page function, LED 02 must
be OFF, and LED 01 can be ON or OFF.

8. Zone relays 1 ~ 4 require a PIOU in the DK16 Expansion Unit.
9. For this option, CO lines must be assigned to ring over external page in Program 78-13.