PROGRAMMING PROCEDURES-INSTRUCTIONS/SYSTEM RECORDS

SECTION 100-816-302

MARCH 1993

NOTES:

1. For more information, see the instructions preceding the record sheets.
2. Initialized data leaves Tables 1 ~ 7 blank; all codes (000 ~ 999) are initialized in Table 8.

3. To enter a range of Area Codes, press:

4. Several ranges or individual codes can be expressed at once by separating them with a

# button.

LCR
Plan

DATA = Area Code(s)

5

LCR
Plan

DATA = Area Code(s)

6

LCR
Plan

DATA = Area Code(s)

7

LCR
Plan

DATA = Area Code(s)

8

000 ~ 999

PROGRAM 51

LCR AREA CODES

H

Z

Z

5

P

S

H

S

Action Code:

Enter 2 to add code to table.
Enter 3 to delete code from table.
Enter 4# to display codes in table.

DATA = Area Code(s)

SELECT = LCR
Plan Number (1 ~ 8)

(3 digits)

1

Denotes end of string

Low Area