Toshiba Strata DK 16 User Manual

Page 117

Advertising
background image

PROGRAMMING PROCEDURES-INSTRUCTIONS/SYSTEM RECORDS

SECTION 100-816-302

MARCH 1993

2-93

PROGRAM 8 (1 ~ 9)

CO LINE/STATION RINGING ASSIGNMENTS

NOTES:
1. For more information, see the instructions preceding the record sheets.
2. Initialized data reads all LEDs ON for Port 00 in Program 81 and Port 01 in Program 87, all other LEDs are OFF.
3. If a CO line must Call Forward or Hunt from a station, the line must be assigned to ring at that station only.
4. A range of ports may be selected.

8

P

S

H

H

Z

Z

assigned to ring selected port number(s)

Button/LEDs = CO Lines

S

Selected CO lines ring selected station ports per Ringing Program options as follows:

8

Immediate

8

12 second delay

8

24 second delay

1

2

3

8

Immediate

8

12 second delay

8

24 second delay

4

5

6

8

Immediate

8

12 second delay

8

24 second delay

7

8

9

SELECT = Logical Port Number(s)
of station(s) that must ring

NIGHT

DAY 2

DAY

SELECT = 1 ~ 9
for type of ringing

CO LED

08
07
06
05
04
03
02
01

Logical Port Numbers

00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19

08
07
06
05
04
03
02
01

NOTE: Shaded areas apply to DK16 only

Advertising