<Self-diagnosis by check codes>

1. The self-diagnosis by the check codes is conducted under the block displays.

2. Remote controller key operation under the service mode is conducted by ON/OFF or TEMP. The remote

controller display by each key operation is varied as shown below. Two digit number is displayed in a hexa-
decimal number.

3. The self-diagnosis by the check codes is conducted with procedures shown below.

1) Enter the service mode and make sure the off timer display of the remote controller shows

“ ”

.

2) Operate the

ON/OFF

key and make sure the timer lamp on the display section is flashing (5 Hz).

3) At the same time, also make sure the operation lamp is also flashing. This shows that the protection

circuit on the indoor P.C. board is working.

4) Operate the TEMP.

key and make sure the remote controller display shows “ ” and flashing of the

operation lamp. If the operation lamp is flashing, it shows the protection circuits for connecting cable is
working or thermal fuse is blown.

5) In the same way, operate the TEMP.

key so that the display is increased one by one to continue checks

by the self-diagnosis as shown in the next table. From

“ ”

up to “ ” check operations of protection

circuits for each block, and

“ ”

to

“ ”

check operations of the typical protection circuits.

Operating key

ON/OFF

TEMP.

(Up)

TEMP.

(Down)

AUTO

LOUVER

SET

LOUVER

Indication after operation

1 is added to data before operation.
(Example)

1 is subtracted from data before operation.
(Example)

10 is subtracted from data before operation.
(Example)

Data before operation is directly transferred.