[F01 error]/[0F error]

[P26 error]/[14 error]

NO

NO

NO

NO

NO

YES

YES

NO

YES

YES

YES

NO

YES

YES

NO

YES

Correct connection of connector.

Replace TCJ sensor.

Improve the power supply line.

Replace IPDU.

Check indoor P.C. board

(MCC-1403).

Defect Replace

Is connection of TCJ sensor connector

(Indoor P.C. board CN102) normal?

Are characteristics of

TCJ sensor resistance value normal?

* Refer to Characteristics-2.

* For RAV-SM560AT-E,

check RY01 on the control P.C. board.

* Single-phase type is not

provided to RAV-SM560AT-E.

* Replace control P.C. board

of RAV-SM560AT-E.

Is power voltage normal?

Is not AC fuse fused?

Check and correct circuit cables.

Correct connection of connector.

Check and correct reactor connection.

Are connections of

cabling/connector normal?

Does RY01 relay of

IPDU operate?

Are not

P26

and

14

errors output

when an operation is performed by

removing 3P connector of compressor?

Replace IPDU.

* Replace control P.C. board

of RAV-SM560AT-E.

Is compressor normal?

Check rare short of compressor trouble.

Defect Replace

Check IPDU.

Defect Replace