54

No.

9

Item

Louver control

1) Louver

position

Outline of specifications

The louver angle is displayed
setting 0

°

as

Full close

.

Remarks

10

1) In the initial operation after

power-ON, the position is
automatically controlled according to the operating
status (COOL/HEAT).

2) After then a louver position is stored in the microcom-

puter every time when position is operated on the
remote controller, and the louver operates at the position
stored in memory in the next operation and after.
* If the operation mode has been changed from COOL

to HEAT, from HEAT to COOL, or the power has
turned off, the stored louver position is cleared and
the status returns to one in item 1).

2) Air direction

adjustment
(Swing
operation)

Frequency fixed
operation
(Test run)

[COOL]/[HEAT] flash.
Air volume: [AUTO]

Temperature

COOL: [L]
HEAT: [H]

Commanded frequency

Approximately [S7]

1) In case of wired remote controller

1. When pushing [ON/OFF] button on the remote

controller continuously for 5 seconds, the mode
enters [TEST]. The indoor fan rotates with [HIGH]
and a frequency fixed operation starts.

2. During this operation, the buttons other than [ON/

OFF], [UP

] and [DOWN

] cannot be accepted.

However, items 7 and 8 are effective.

3. To stop the frequency fixed operation, use [ON/OFF]

button only.

2) In case of wireless remote controller (Without wired

remote controller)

1. When pushing [Temporary] button continuously for

10 seconds or more,

Pi

sound is heard and the

mode enters [TEST]. The indoor fan rotates with
[HIGH] and a frequency fixed operation of [COOL]
starts.

NOTES :

Temporary button is provided to near the display part of
the main unit when opening the front panel.

If [Temporary] button is not continuously pushed for 10
seconds,

Automatic heating/cooling operation

is

performed.

2. To stop the operation, push [Temporary] button again.

NOTE :
Operation on the wireless remote controller is not ac-
cepted.

1) When pushing [LOUVER] button during operation, the

louver starts swinging.

2) When the louver has arrived at the desired position, push

[LOUVER] again. The louver stops at that position.

0

Full close

45

103

Cooling

Heating

Advertising