9-1-3. Control Specifications

No.

1

Item

When power
supply is reset

Outline of specifications

1) Distinction of outdoor units

When the power supply is reset, the outdoors are
distinguished, and control is exchanged according to
the distinguished result.

2) Setting of the indoor fan speed

Based on EEPROM data, rspeed of the indoor fan is
selected.

1) Based on the operation mode selecting command

from the remote controller, the operation mode is
selected.

Remarks

Air speed

Remote controller

command

STOP

FAN

COOL

DRY

HEAT

AUTO

Outline of control

Air conditioner stops.

Fan operation

Cooling operation

Dry operation

Heating operation

1) Judge the selection of COOL/HEAT mode as shown in the

figure below.
When the heating operation (Thermo OFF) is exchanged
to cooling operation if Tsh exceeds +3 or more.
(COOL OFF) and (COOL ON) in the figure indicate an
example.
When the cooling operation (Thermo OFF) is exchanged
to heating operation if Tsc exceeds -3 or less.

2) For the automatic capacity control after judgment of

COOL/HEAT, refer to item 4.

3) For the temperature correction of room temperature control

in automatic heating operation, refer to item 3.

Ta

: Room temperature

Ts : Setup temperature

Tsc : Setup temperature

in cooling operation

Tsh : Setup temperature

in heating operation

1) Adjustment range Remote controller setup tempera-

ture (

°

C)

2

3

Operation mode
selection

Room tempera-
ture control

Standard type

Wireless type

COOL/

DRY

18 to 29

17 to 30

Heating

operation

18 to 29

17 to 30

Auto

operation

18 to 29

19 to 29

Remote controller
setup temp

Setup temp (

°

C)

5

4

3

2

1

19

20

21

22

23

Standard

24

1

2

3

4

5

25

26

27

28

29

2) Differential 1K (=deg)
3) In heating operation, the setup temperature can be

corrected by using Dip switch (SW03) on the indoor
P.C. board.

Setup at shipment

Max. setup temperature
Ts (Max) = 35

°

C

SW03

1

2

Setup temp correction

ON

ON

OFF

OFF

ON

OFF

ON

OFF

+0

°

C +2

°

C +4

°

C +6

°

C

SW03

1

2

ON

OFF

Ta

(

C)

+3

Tsc

or Tsh

3

Heating

COOL

(COOL ON)

(COOL OFF)