Concealed duct type rav-sm560bt-e – Toshiba RAV-SM560BT-E User Manual

Page 14

Advertising
background image

– 14 –

Concealed Duct Type

RAV-SM560BT-E

170

120

20

70

252

280

750 ± 7.5 Hanging bolt pitch
700 Dimension of main unit

150

160~640

5

730

780 Ceiling opening size

80

60

457 to 637

75

720

210

509

630

300

130

80

30

35

90

120

305

314.5

240

211

45

Refrigerant pipe

connecting port

(Gas side Ø12.7)

80

170

155 to 335

30

320

210

170

100

70

450

150

450

2-Ø200

Discharge port flange

4-M10

Hanging bolt

(Procured locally)

For hanging bolt M10

(4-12 x 25 long hole)

25

25

800 Dimension of main unit

565 Hanging bolt pitch

Drain pipe connecting port

at drain up kit side

(For polyvinyl chloride pipe

(Inner dia. 32, Nominal dia. 25))

Refrigerant pipe

connecting port

(Liquid side Ш6.4)

Ш125 knockout hole (Only rear side)

(For air suction)

6-Ø4 tapping screw lower hole Ø160

Suction port canvas

Suction panel

470 Ceiling opening size

Panel

2-Ø26 power supply remote

controller cord draw-out port

Drain pipe connecting port

at main unit side

(For polyvinyl chloride pipe

(Inner dia. 32, Nominal dia. 25))

Plane view of main unit

Check port A

(Pipe side)

Discharge side

NOTE 1 :

For maintenance of the equipment, be sure to install

a check port A at the position as shown below.
NOTE 2 :

Using the drain up kit sold separately, drain-up by 300 (mm)

from drain pipe draw-out port of the main unit is necessary.

The drain-up over 300mm or more is impossible.

Drain up kit

(Sold separately)