5.24 Receive Maximum Length Register (RXMAXLEN)

EMAC Port Registers

The receive maximum length register (RXMAXLEN) is shown in

Figure 52

and described in

Table 52

.

Figure 52. Receive Maximum Length Register (RXMAXLEN)

31

16

Reserved

R-0

15

0

RXMAXLEN

R/W-1518

LEGEND: R/W = Read/Write; R = Read only; -n = value after reset

Table 52. Receive Maximum Length Register (RXMAXLEN) Field Descriptions

Bit

Field

Value

Description

31-16

Reserved

0

Reserved

15-0

RXMAXLEN

Receive maximum frame length. These bits determine the maximum length of a received frame.
The reset value is 5EEh (1518). Frames with byte counts greater than RXMAXLEN are long
frames. Long frames with no errors are oversized frames. Long frames with CRC, code, or
alignment error are jabber frames.

Ethernet Media Access Controller (EMAC)/Management Data Input/Output (MDIO)