4.13 MDIO User PHY Select Register 0 (USERPHYSEL0)

MDIO Registers

The MDIO user PHY select register 0 (USERPHYSEL0) is shown in

Figure 27

and described in

Table 26

.

Figure 27. MDIO User PHY Select Register 0 (USERPHYSEL0)

31

16

Reserved

R-0

15

8

7

6

5

4

0

Reserved

LINKSEL

LINKINTENB

Reserved

PHYADRMON

R-0

R/W-0

R/W-0

R-0

R/W-0

LEGEND: R = Read only; R/W = Read/Write; -n = value after reset

Table 26. MDIO User PHY Select Register 0 (USERPHYSEL0) Field Descriptions

Bit

Field

Value

Description

31-8

Reserved

0

Reserved

7

LINKSEL

Link status determination select bit. Default value is 0 which implies that the link status is
determined by the MDIO state machine. This is the only option supported on this device.

6

LINKINTENB

Link change interrupt enable. Set to 1 to enable link change status interrupts for PHY address
specified in PHYADRMON. Link change interrupts are disabled if this bit is set to 0.

0

Link change interrupts are disabled

1

Link change status interrupts for PHY address specified in PHYADDRMON bits are enabled

5

Reserved

0

Reserved

4-0

PHYADRMON

PHY address whose link status is to be monitored