4.6

MDIO Link Status Change Interrupt (Unmasked) Register (LINKINTRAW)

MDIO Registers

The MDIO link status change interrupt (unmasked) register (LINKINTRAW) is shown in

Figure 20

and

described in

Table 19

.

Figure 20. MDIO Link Status Change Interrupt (Unmasked) Register (LINKINTRAW)

31

16

Reserved

R-0

15

2

1

0

Reserved

LINKINTRAW

R-0

R/WC-0

LEGEND: R = Read only; R/WC = Read/Write 1 to clear; -n = value after reset

Table 19. MDIO Link Status Change Interrupt (Unmasked) Register (LINKINTRAW) Field

Descriptions

Bit

Field

Value

Description

31-2

Reserved

0

Reserved

1-0

LINKINTRAW

MDIO Link change event, raw value. When asserted, a bit indicates that there was an MDIO link
change event (i.e. change in the LINK register) corresponding to the PHY address in the
USERPHYSEL register. LINKINTRAW[0] and LINKINTRAW[1] correspond to USERPHYSEL0 and
USERPHYSEL1, respectively. Writing a 1 will clear the event and writing 0 has no effect.