– 101 –

12-3. Outdoor Unit

No.



Part name

Common

procedure

Procedure

1. Detachment

NOTE

Wear gloves for this job.
Otherwise, you may injure your
hands on the parts, etc.

1) Stop operation of the air conditioner,

and turn off the main switch of the

breaker for air conditioner.

2) Remove the valve cover.

(screw 3 pcs.)
• After removing screw, remove the

valve cover pulling it downward.

3) Remove cord clamp (screw 3 pcs.)

and then remove connecting

cable.

4) Remove the upper cabinet.

(screw

5 pcs.)

• After removing screws, remove the

upper cabinet pulling it upward.

2. Attachment

1) Attach the upper cabinet.

Remarks

FILE NO. SVM-10019

(screw 5 pcs.)

2) Perform cabling of connecting cable,

and attach the cord clamp.

Fix the cord clamp by tightening

the screws (screw 3 pcs.)
fitting 2 concave parts of the cord
clamp to each connecting cables.

3) Attach the valve cover.

(screw 3 pcs.)

Insert the upper part into the square

hole of the side cabinet, set hook
claws of the valve cover to square
holes (at two positions) of the main
unit, and attach it pushing upward,

Advertising