Toshiba RAS-09LKV-UL User Manual

Page 36

Advertising
background image

Horizontal

blowing

Inclined

blowing

Blowing

downward

Air direction

Inclined

blowing

Horizontal

blowing

Initial setting of "Cooling storage position"
Louver : Directs downward (35.3°)

Heating operation/

AUTO (HEAT)

Initial setting of “Heating storage position”

Louver : Directs downward (80.5 )

Item

8. Louver control

1) Louver

position

Operation flow and applicable data, etc.

This function controls the air direction of the indoor unit.

Description

• Swing operation is perfor in range 35° with the Fixed position as

the center.

• If the swing range exceeded either upper or lower limit position,

swing operation is perfomed in range 35° from the limit.

3) Swing

2) Louver position in heating operation

2) Air direction adjustment

• The position is automatically controlled according to the operation

• The set louver position is stored in memory by the microcomputer,

The angle of the louver is indicated as the louver closes fully is 0°.

1) Louver position in cooling operation

mode (COOL/HEAT).

and the louver returns to the stored position when the next operation

is performed. (Cooling/Heating memory position)

• Swing

When pressing
[SWING] button during
operation, the louver
starts swinging.

• The louver position can

be arbitrarily set up by
pressing [FIX] button.

– 36 –

FILE NO. SVM-10019

Fixed
Position
before start
swing

Upper Limit
Position.

Lower Limit
Position

30

o

5

o

Swing
range 35

o

Upper Limit
Position.

Lower Limit
Position.

Fixed Position
before start
swing.

17.5

o

17.5

o

Swing
range 35

o