Toshiba RAS-09LKV-UL User Manual

Page 90

Advertising
background image

– 90 –

11-8-3. Indoor Unit (Other Parts)

11-8-4. Outdoor Unit

No.

1

Part name

Room temp. (TA) sensor

Heat exchanger (TC) sensor

Checking procedure

Disconnect the connector and measure the resistance value with tester.

(Normal temp.)

No.

1

Part name

Compressor

(Model : DA111A1F-20F2)

Checking procedure

Measure the resistance value of winding by using the tester.

Red

White

Black

Red

White

Black

Measure the resistance value of winding by using the tester.

Resistance value

1435 ± 144

at 20°C

Measure the resistance value of winding by using the tester.

COM

COM

2 5 4

Y

W

R BL

1

GR

6

O

3

Position

Gray - White

Gray - Orange

Red- Yellow

Red- Blue

Resistance value

42 to 50

42 to 50

42 to 50

42 to 50

Temperature

Sensor

TA, TC (k

)

10°C

20°C

25°C

30°C

40°C

20.7

12.6

10.0

7.9

4.5

5

4

3

2

1

White

Yellow

Yellow

Yellow

Yellow

5

4

3

2

1

Refer to 11-5-1. (5).
Measure the resistance value of each winding coil by using the tester.

(Under normal temp. 25°C)

Position

1 to 2

1 to 3

1 to 4

1 to 5

Resistance value

250 ± 20

Refer to 11-5-1. (3) and (4).

at 20°C

Disconnect the connector, and measure resistance value with the tester.

(Normal temperature)

Outdoor temperature sensor

(TO), discharge temperature

sensor (TD), suction

temperature sensor (TS),

outdoor heat exchanger

temperature sensor (TE)

Temperature

Sensor

TD (k

)

TO,TS,TE (k

)

10°C

20°C

25°C

30°C

40°C

50°C

100

64

50

41

27

18

20.7

12.6

10.0

7.9

4.5

2
3

Remote controller
Louver motor

MP24Z3T

4

Indoor fan motor

Measure the resistance value of each winding by using the tester.

Position

Red - White

White - Black

Black - Red

Resistance value

0.88 to 0.98

at 20ºC

DA111A1F-20F1

DA89X1C-1F-23FZ

1.04 to 1.16

Position

Red - White

White - Black

Black- Red

Resistance value

20 to 22

20 to 22

20 to 22

2

3

4

5

Outdoor fan motor

(Model : ICF-340UA0-2)

4-way valve coil

(Model : STF)

Pulse motor valve coil

(Model : CAM-MD12TCTH-4)

RAS-12LAV-UL

(Model : DA89X1C-23FZ2)

RAS-09LAV-UL

FILE NO. SVM-10019

at 20ºC

Advertising
This manual is related to the following products: