Specifications of electrical parts, 1. indoor unit, 2. outdoor unit – Toshiba RAS-09LKV-UL User Manual
Page 20
– 20 –
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
L = 10mH, 16A
2
Outdoor fan motor
3
Suction temp. sensor (TS sensor)
10k
Ω (25°C)
4
Discharge temp. sensor (TD sensor)
62k
Ω (20°C)
5
Outside air temp. sensor (TO sensor)
10k
Ω (25°C)
6
Heat exchanger temp. sensor (TE sensor)
10k
Ω (25°C)
7
Terminal block (5P)
30A, AC600V
RAS-09LAV-UL
RAS-12LAV-UL
9
COIL FOR P.M.V.
DC12V
10
Coil for 4-way valve
CAM-MD 12TCTH-4
STF
Compressor
(Inverter attached)
(Inverter attached)
(Inverter attached)
8
(Inverter attached)
DA89X1C-23FZ2
DA111A1F-20F2
CH-57
ICF-340UA40-2 DC340V, 40W
11 Pressure SW.
ACB-4UB82W
4.7 MPa
RAS-09LKV-UL
(for indoor) RAS-12LKV-UL
2 Room temp. sensor (TA-sensor)
10k
Ω
at 25°C
3
Heat exchanger temp. sensor (TC-sensor)
10k
Ω at 25°C
4 Louver motor
Output (Rated) 1W, 16 poles, DC12V
(
− )
(
−
)
MP24Z3T
AFS-220-20-4D AC240V, 20W
1
ICF-340U30-2 AC220V, 20W
No.
Fan motor
Parts name
Specifications
Type
No. Parts name Model name Rating
Reactor
1
3-phases 4-poles 750W
3-phases 4-poles 680W
FILE NO. SVM-10019
6-2. Outdoor Unit