Toshiba RAS-09LKV-UL User Manual

Page 54

Advertising
background image

– 54 –

10-2-3. Installation/Servicing Tools

Changes in the product and components

In the case of an air conditioner using R410A, in order to prevent any other refrigerant from being charged

accidentally, the service port diameter of the outdoor unit control valve (3 way valve) has been changed.

(1/2 UNF 20 threads per inch)
• In order to increase the pressure resisting strength of the refrigerant piping flare processing diameter and size

of opposite side of flare nuts has been changed. (for copper pipes with nominal dimensions 1/2 and 5/8)

New tools for R410A

New tools for R410A

Gauge manifold

Charge hose

Electronic balance

for refrigerant charging

Torque wrench

(nominal diam. 1/2, 5/8)

Flare tool (clutch type)

Gauge for projection

adjustment

Vacuum pump adapter

Gas leakage detector

Applicable to R22 model

Ч
Ч

¡

Ч

¡

¡

Ч

Changes

As pressure is high, it is impossible to measure by means of

conventional gauge. In order to prevent any other refrigerant from

being charged, each port diameter has been changed.

In order to increase pressure resisting strength, hose materials

and port size have been changed (to 1/2 UNF 20 threads per inch).

When purchasing a charge hose, be sure to confirm the port size.

As pressure is high and gasification speed is fast, it is difficult to

read the indicated value by means of charging cylinder, as air

bubbles occur.

The size of opposite sides of flare nuts have been increased.

Incidentally,

a common wrench is used for nominal diameters 1/4 and 3/8.

By increasing the clamp bar’s receiving hole, strength of spring in

the tool has been improved.

Used when flare is made by using conventional flare tool.

Connected to conventional vacuum pump. It is necessary to use

an adapter to prevent vacuum pump oil from flowing back to the

charge hose. The charge hose connecting part has two ports-one

for conventional refrigerant (7/16 UNF 20 threads per inch) and

one for R410A. If the vacuum pump oil (mineral) mixes with R410A

a sludge may occur and damage the equipment.

Exclusive for HFC refrigerant.

• Incidentally, the “refrigerant cylinder” comes with the refrigerant designation (R410A) and protector coating in the

U. S’s ARI specified rose color (ARI color code: PMS 507).

• Also, the “charge port and packing for refrigerant cylinder” require 1/2 UNF 20 threads per inch corresponding to

the charge hose’s port size.

FILE NO. SVM-10019

Advertising