2. outdoor unit (inverter assembly), Micr o-computer block dia gram – Toshiba RAS-09LKV-UL User Manual

Page 25

Advertising
background image

– 25 –

8-2. Outdoor Unit (Inverter Assembly)

208/230-1-60

MICR

O-COMPUTER BLOCK DIA

GRAM

Driver circuit of P.M.V.

Heat exchanger temp.sensor

Suction temp.

sensor

Outdoor air temp. sensor

Discharge temp. sensor

Indoor unit send/receive

circuit

Relay circuit

Noise Filter

Converter (AC

DC)

Clock

frequency

4MHz

High Power

factor Correction

circuit

Input current

sensor

• PWM synthesis function

• Input current release control

• IGBT over-current detect control

• Outdoor fan control

• High power factor correction control

• Inverter output frequency control

• A/D converter function

• P.M.V. control

• Discharge temp. control

• 4-way valve control

• Signal communication to indoor unit

P.M.V.

: Pulse Motor Valve

M.C.U. : Micro Control Unit

M.C.U

For INDOOR UNIT

4-way valve

P.M.V.

Inverter

(DC

AC)

Gate drive

circuit

Gate drive

circuit

Inverter

(DC

AC)

Outdoor Fan motor

Compressor

MCC5009 (P

.C.B)

OUTDOOR UNIT

Current detect

Current detect

FILE NO. SVM-10019

Advertising