– 108 –

No.

11

Part name

Procedure

Remarks

TE sensor (outdoor heat exchanging temperature sensor)

• Attachment

Install the sensor onto the straight pipe part of the condenser

output pipe.

During the installation work (and on its completion), take care not to damage the coverings of

the sensor leads on the edges of the metal plates or other parts. It is dangerous for these

coverings to be damaged since damage may cause electric shocks and/or a fire.

CAUTION

After replacing the parts, check whether the positions where the sensors were installed are the

proper positions as instructed. The product will not be controlled properly and trouble will result

if the sensors have not been installed in their proper positions.

Detail C for 12LAV-UL

Detail C for 09LAV-UL

TS sensor (Suction pipe temperature sensor)

• Attachment

Install the senser onto the straight pipe part of the suction

pipe. Be careful for the lead direction of the sensor.

TD sensor (Discharge pipe temperature sensor)

• Attachment

With its leads pointed upward, install the sensor onto the

vertical straight pipe part of the discharge pipe.

TO sensor (Outside air temperature sensor)

• Attachment

Insert the outdoor air temperature sensor into the holder, and

install the holder onto the heat exchanger.

12

13

14

CAUTION

FILE NO. SVM-10019

Detail A for 09,12LAV-UL

TD sensor

TO sensor