Toshiba RAS-09LKV-UL User Manual

Page 104

Advertising
background image

– 104 –

No.

„

Part name

Control board

assembly

Procedure

1. Disconnect the leads and connectors connected to

the other parts from the control board assembly.
1) Leads

• 3 leads (black, white, orange) connected to

terminal block.

• Lead connected to compressor :

Disconnect the connector (3P).

• Lead connected to reactor :

Disconnect the two connectors (2P).

2) Connectors (×8)

CN300 : Outdoor fan motor (3P: white)*

(* : See

Note

)

CN701 : 4-way valve (2P: yellow)*
CN600 : TE sensor (2P: white)*
CN700 : PMV (6P: white)
CN603 : TS sensor (3P: white)*
CN601 :TD sensor (3P: white)*
CN602 : TO sensor (2P: white)

NOTE

These connectors have a disconnect prevention

mechanism: as such, the lock on their housing

must be released before they are disconnected.

2. Remove the control board assembly from the P.C.

board base. (Remove the heat sink and control

board assembly while keeping them screwed

together.)

NOTE

Disengage the four claws of the P.C. board base,

hold the heat sink, and lift to remove it.

3. Remove the two fixing screws used to secure the

heat sink and control board assembly.

4. Mount the new control board assembly.

NOTE

When mounting the new control board assembly,

ensure that the P.C. board is inserted properly

into the P.C. board support groove.

Remarks

CN300, CN701, CN600 and

CN603 are connectors with

locking mechanisms: as such,

to disconnect them, they must

be pressed in the direction of

the arrow while pulling them

out.

P.C. board base

P.C. board

CN700

CN602

CN300

CN701

CN603

CN601

CN600

FILE NO. SVM-10019