43 video standard select, 44 frequency request, 101 external controls – Vidikron VP-60 User Manual

Page 102

Advertising
background image

101

External Controls

43 VIDEO STANDARD SELECT

Function

The external control equipment sets the VIDEO STANDARD of the plasma monitor.

Transmission Data

DFH

80H

60H

5CH

01H

DATA00 CKS

DATA00: 01H: 3.58NTSC

02H: 4.43NTSC
03H: PAL
04H: SECAM
05H: AUTO1
0BH: PAL60
0CH: AUTO2
0DH: PAL-M
0EH: PAL-N

ACK

7FH

60H

80H

5CH

01H

DATA00 CKS

DATA00: 01H: 3.58NTSC

02H: 4.43NTSC
03H: PAL
04H: SECAM
05H: AUTO1
0BH: PAL60
0CH: AUTO2
0DH: PAL-M
0EH: PAL-N

44 FREQUENCY REQUEST

Function

The external control equipment inquires the Horizontal frequency, Vertical frequency,

Horizontal sync polarity, Vertical sync polarity, Mode, and Resolution of the plasma

monitor.

Transmission Data

1FH

80H

60H

26H

00H

CKS

ACK

7FH

60H

80H

26H

0BH

DATA00 to DATA10

CKS

Horizontal frequency

DATA00: Integer part

00H: 0 (No signal: 00H)

|

FFH: 256

DATA01: One decimal place

00H: 0 (No signal: 00H)

|

09H: 9

Vertical frequency

DATA02: Integer part

00H: 0 (No signal: 00H)

|

FFH: 256

DATA03: One decimal place

00H: 0 (No signal: 00H)

|

09H: 9

Horizontal sync polarity

DATA04: 00H: -

01H: Positive

02H: Negative

Advertising