43 video standard select, 44 frequency request, 101 external controls – Vidikron VP-60 User Manual
Page 102
101
External Controls
43 VIDEO STANDARD SELECT
Function
The external control equipment sets the VIDEO STANDARD of the plasma monitor.
Transmission Data
DFH
80H
60H
5CH
01H
DATA00 CKS
DATA00: 01H: 3.58NTSC
02H: 4.43NTSC
03H: PAL
04H: SECAM
05H: AUTO1
0BH: PAL60
0CH: AUTO2
0DH: PAL-M
0EH: PAL-N
ACK
7FH
60H
80H
5CH
01H
DATA00 CKS
DATA00: 01H: 3.58NTSC
02H: 4.43NTSC
03H: PAL
04H: SECAM
05H: AUTO1
0BH: PAL60
0CH: AUTO2
0DH: PAL-M
0EH: PAL-N
44 FREQUENCY REQUEST
Function
The external control equipment inquires the Horizontal frequency, Vertical frequency,
Horizontal sync polarity, Vertical sync polarity, Mode, and Resolution of the plasma
monitor.
Transmission Data
1FH
80H
60H
26H
00H
CKS
ACK
7FH
60H
80H
26H
0BH
DATA00 to DATA10
CKS
Horizontal frequency
DATA00: Integer part
00H: 0 (No signal: 00H)
|
FFH: 256
DATA01: One decimal place
00H: 0 (No signal: 00H)
|
09H: 9
Vertical frequency
DATA02: Integer part
00H: 0 (No signal: 00H)
|
FFH: 256
DATA03: One decimal place
00H: 0 (No signal: 00H)
|
09H: 9
Horizontal sync polarity
DATA04: 00H: -
01H: Positive
02H: Negative