04 VOLUME GAIN DATA
Function
The external control equipment changes the VOLUME gain data of the plasma monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER SOUND Gain Flag
05H
DATA01: VOLUME Gain Flag
01H
DATA02: VOLUME Gain
00H: Step 0
|
0AH: Step 10 (Default)
|
2AH: Step 42
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER SOUND Gain Flag
05H
DATA01: VOLUME Gain Flag
01H
05 AUDIO MUTE ON
Function
The external control equipment switches on AUDIO Mute of the plasma monitor.
Transmission Data
9FH
80H
60H
3EH
00H
CKS
ACK
3FH
60H
80H
3EH
00H
CKS
06 AUDIO MUTE OFF
Function
The external control equipment switches off AUDIO Mute of the plasma monitor.
Transmission Data
9FH
80H
60H
3FH
00H
CKS
ACK
3FH
60H
80H
3FH
00H
CKS
07 CONTRAST GAIN DATA
Function
The external control equipment changes the CONTRAST gain data of the plasma
monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
051H
DATA01: CONTRAST Gain Flag
07H
DATA02: CONTRAST Gain
CCH: -52
|
FFH: -01
00H: 0
01H: +01
|
14H: +20
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: CONTRAST Gain Flag
07H