10 color gain data, 11 tint gain data, 85 external controls – Vidikron VP-60 User Manual
Page 86
85
External Controls
10 COLOR GAIN DATA
Function
The external control equipment changes the COLOR gain data of the plasma monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: COLOR Gain Flag
04H
DATA02: COLOR Gain
E0H: -32
* COLOR Gain is from -22 (EAH) to
+22 (16H) only during video
|
FFH: -01
00H: 0
01H: +01
|
20H: +32
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: COLOR Gain Flag
04H
11 TINT GAIN DATA
Function
The external control equipment changes the TINT gain data of the plasma monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: TINT Gain Flag
05H
DATA02: TINT Gain
E0H: -32
|
FFH: -01
00H: 0
01H: +01
|
20H: +32
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: TINT Gain Flag
05H